System · NFPA 11 · EN 13565 · FM Global

Industrial Foam & Deluge Systems

High-performance foam suppression engineered for fuel storage, port terminals, refineries, aircraft hangars, and large-scale industrial hazards — where water alone is not sufficient.

Technology Partner

Viking Corporation — Foam Systems

Viking Corporation is one of the world's leading manufacturers of fire protection systems. Their foam system components carry FM Approval (to FM 5130) and UL Listing (to UL 162), providing the highest level of assurance for critical hazard environments.

Viking Corporation

Deluge Foam-Water System — Bladder Tank Configuration

The Viking Deluge Foam-Water System delivers a precisely proportioned foam-water solution through open sprinklers, spray nozzles, and monitor nozzles to the protected hazard area. The bladder tank configuration uses a hydraulically actuated Viking Halar®-coated concentrate control deluge valve, ensuring accurate foam proportioning without the need for a separate pump. The system activates automatically via fire detection devices — IR3 flame detectors, heat detectors, or rate-of-rise — and discharges the foam solution immediately throughout the hazard area.

  • Viking Halar® Deluge Valve
  • Bladder Tank Proportioning
  • FM Approved · UL Listed
  • NFPA 11 & 16 Compliant
  • Multiple Riser Configuration
  • Pneumatic / Hydraulic / Electric Release
  • Hi-Ex & Lo-Ex Foam
Viking Corporation — SFFF

Fluorine-Free Foam Systems (SFFF)

Viking's Synthetic Fluorine-Free Foam (SFFF) systems provide high fire performance without the environmental concerns associated with AFFF concentrates containing PFOS/PFOA. SFFF is biodegradable, contains no intentionally added fluorinated surfactants, and has zero ozone depletion potential. Viking's SFFF systems are tested and approved for use with FM Approved and UL Listed Viking sprinkler heads, ensuring the complete system — foam concentrate, proportioning device, and discharge device — meets recognized performance standards. Suitable for Class B hydrocarbon fuel fires and Class A hazards.

  • Zero PFOS / PFOA
  • FM 5130 Approved System
  • Biodegradable
  • Class A & B Fires
  • NFPA 11 & EN 13565-2
  • Compatible with Viking Sprinklers
  • LoEx Foam Estimator Tool
FAS Engineering & HD Fire

Foam Monitors & Proportioning Equipment

Fixed and oscillating foam monitors (water cannons) for unconfined spill fire protection, loading rack protection, and open-air hazard areas at ports and refineries. Hydraulically actuated monitor nozzles deliver high-flow foam solution across large coverage areas without requiring personnel in the hazard zone. Paired with inline proportioners, around-the-pump proportioners, or bladder tank systems depending on flow requirements and available water pressure.

  • Fixed & Oscillating Monitors
  • Hydraulic & Electric Actuation
  • Inline Proportioners
  • Around-the-Pump Proportioners
  • High-Flow Nozzles
  • Port & Refinery Rated
Applications

Where We Apply Foam Systems

NFPA 11 and EN 13565-2 govern foam system design. Requirements for foam systems are also found in NFPA 13, 16, 30, 409, and 418 depending on the application.

🛢️

Fuel Storage Tanks

Fixed and semi-fixed foam systems for floating roof and cone roof tanks. Foam chambers, rim seal protection, and sub-surface injection to NFPA 11.

Port & Marine Terminals

Foam monitor systems for dangerous goods storage areas, tanker loading berths, and open-air liquid fuel handling — including oscillating monitor installations.

✈️

Aircraft Hangars

High-expansion foam systems to NFPA 409 for enclosed hangar protection. Low-expansion systems for fuel pit and apron area coverage.

⚗️

Refineries & Petrochemical

Comprehensive foam protection for process areas, pump houses, loading racks, and transformer bunds in high-hazard industrial environments.

🏭

Industrial Facilities

Foam-water deluge systems for incineration plants, logistics centers, paint spray booths, and areas with flammable liquid spill fire risk.

🔋

Transformer Protection

Water-spray and foam systems for oil-filled transformer bunds and switchgear rooms, designed to NFPA 15 and FM DS 5-4.